Measurements in nuclear power plantsMeasurements:- Response time of the PT200 temperature sensors (estimate).
- Leak detection in the reactor enclosure.
- Friction on control rods.
- Torque load on fuel container cover bolts.
- Leakage rate of steam generator tubes.
Calibrations:- On- site: test bench for shock absorbers, leak detectors on reactor enclosures, and cross calibration of PT200 RTD sensors.
- In laboratory: pressure sensors (absolute, relative, and differential), flow meters, displacement sensors, force sensors, and temperature measurement.

Contact: Thierry DEBORSU P: +32 (0)2 382 0330
|
|
| |
|
|
© Laborelec, Rodestraat 125, B-1630 Linkebeek, Belgium, phone: +32 (0) 2 382 02 11, fax: +32 (0) 2 382 02 41, e-mail: info@laborelec.com |