Integrity Assessment and failure analysis: BoilersFailure analysis. This can include: - Root cause analysis.
- Material examination.
It often results in: - Repair and/or replace advice.
- Advice on follow-up checks.
- Weld advice.
Destructive and non-destructive examination during overhauls, resulting in repair and/or replacement advice.Predictive maintenance programs for boilers: - Total approach, starting with collation of design and operating data and the identification of critical points.
- Choosing the most appropriate and accurate tests to investigate corrosion, creep, and thermal fatigue.
- Design of special new testing techniques when required.
- Calculation of the residual life, using these results in combination with our modelling software.
- Drafting a tailor-made maintenance plan that includes future inspections and component replacements, and that avoids superfluous inspections yet ensures the required safety margin.
|
| |
| |
|
|